+86 15657752999
12kV Gapless Polymer Surge Arrester YH5(10)W-12 from China Suppliers and Factory for Overhead Transformers
Product Overview
The YH5(10)W-12 and YH5(10)W-12J are gapless, polymer-housed surge arresters rated at 12kV, purpose-built for overhead distribution line transformer protection. They employ high-quality zinc oxide varistors to rapidly conduct overvoltage energy from lightning strikes and switching surges safely to ground. Designed in full compliance with IEC60099-4:2014, these arresters deliver dependable, long-lasting performance in heavy pollution areas and at altitudes up to 1000 meters.
Product Features
Rated voltage 12kV, with selectable nominal discharge current of 5kA or 10kA.
Superior surge protection: lightning impulse residual voltage ≤36kV (crest), steep current impulse residual voltage ≤42.2kV (crest), switching impulse residual voltage ≤31.7kV (crest).
Robust energy handling capacity: withstands long duration current impulses up to 250A and high current impulses up to 100kA (crest).
Durable polymer housing in dark grey or light grey, with stainless steel 304 upper terminal (M12) and lower terminal (M10).
Flexible configuration with optional NEMA A/B mounting bracket, disconnector, earth lead, bird guard cap, and line clamp.
Engineered for heavy pollution levels, maximum ambient temperature 40°C, and 50Hz rated frequency.
Product Advantages
Fast, reliable overvoltage protection through gapless zinc oxide technology, eliminating follow current and reducing equipment damage risk.
Comprehensive surge handling covers lightning, steep current, and switching impulses, ensuring all-around transformer safety.
Lightweight, high-strength polymer housing outperforms traditional porcelain with superior pollution performance and safer failure mode.
Full IEC60099-4:2014 compliance assures internationally benchmarked quality and safety for global power distribution applications.
Application Scenarios
Overhead distribution line transformer surge protection (primary use case).
Class 1 or Class 2 distribution-type arrester installations in urban and rural power networks.
Lightning-intensive regions requiring robust and fast-responding overvoltage suppression.
Heavy pollution environments at altitudes up to 1000 meters, where reliable outdoor insulation performance is critical.
Technical Parameter
| Electrical characteristics | Specification | Unit | |
|---|---|---|---|
| Rated voltage of Surge arrreser | 12 | kV | |
| Nominal discharge current | 5 | 10 | kA |
| Rated frequency | 50 | Hz | |
| Maximum continuous operating voltage | 10.2 | kV | |
| Steep current impulse residual voltage | 42.2 | kV(Crest) | |
| Lightning Impulse residual voltage | 36 | kV(Crest) | |
| Switching Impulse residual voltage | 31.7 | kV(Crest) | |
| Long duration current impulse withstand voltage | 150 | 250 | A |
| High current impulses | 65 | 100 | kA (Crest) |
| Rated Short-circuit current | 20 / 12 / 6 / 0.6 ± 0.2 | kA | |
| Class of Surge arrester | Class 1 or Class 2 | ||
| Application | Distribution type | ||
| With or without gap | Gapless | ||
| Designation of arrester | Design B | ||
| Spare parts | |
|---|---|
| NEMA A or B mounting bracket | with/without |
| Disconnector | with/without |
| Earth lead | with/without |
| Bird guard cap | with/without |
| Line clamp | with/without |
| Upper terminal (incoming line) bolt size | M12 |
| Lower termina (outgoing line) bolt size | M10 |
| Material | |
|---|---|
| Upper terminal | Stainless steel 304 |
| Housing | Polymer type |
| Color of housing | Dark grey / light grey |
| Varistor | High quality zinc oxide varistor |
| Size of Varistor | 35mm / 38mm / 40mm / 42mm |
| Service conditions | Value | Unit |
|---|---|---|
| Environment maximum temperature | 40 | °C |
| Pollution level | Heavy | - |
| Altitude | 1000 | Meter |
Frequently Asked Questions (FAQ)
They are purpose-built for overhead distribution line transformer surge protection, suitable for Class 1 and Class 2 distribution applications in urban and rural power systems.
The arresters are engineered and tested in full compliance with the international standard IEC60099-4:2014.
The rated voltage is 12kV (with maximum continuous operating voltage of 10.2kV), available with a selectable nominal discharge current of either 5kA or 10kA.
The unit features high-grade polymer housing (dark grey or light grey), high-quality zinc oxide varistors (sizes 35mm, 38mm, 40mm, or 42mm), and stainless steel 304 upper (M12) and lower (M10) terminals.
Optional spare parts include NEMA A or B mounting brackets, disconnectors, earth leads, bird guard caps, and line clamps according to project requirements.
The arresters are designed for harsh outdoor installations with heavy pollution levels, maximum ambient operating temperatures up to 40°C, and altitudes up to 1000 meters at a 50Hz rated grid frequency.
Inquire Now!
If you have any needs, please feel free to contact me and I will be happy to serve you.