HFSC-30F Drop Out Fuse Cutout - China Suppliers and Factory for 11kV-38kV Overhead Distribution Protection

The HFSC-30F is a high-performance loadbreak fuse cutout from the HFSC polymer type series, expertly designed for overcurrent fault protection in 11kV–38kV overhead distribution networks. This product, made by leading suppliers in China, utilizes standard fuse links to safeguard vital assets such as transformers, capacitor banks, cables, and feeder lines from short-circuit and overload incidents. With its durable polymer housing and premium materials, the HFSC-30F ensures reliable service in various outdoor environments, making it an essential choice for factories looking to enhance the safety and efficiency of their power distribution systems.

    Product Advantages

    Loadbreak function permits safe disconnection of live circuits under normal load conditions

    Premium conductive materials, including silver-plated copper, maximize current transfer efficiency and resist oxidation

    Polymer insulator selection reduces overall weight and delivers outstanding hydrophobic performance in wet or polluted settings

    Configurable spare parts and mounting options simplify on-site assembly and maintenance

    International standard compliance guarantees consistent performance and broad market acceptance

    Applications

    24–27kV overhead distribution feeders

    Transformer and capacitor bank overcurrent safeguarding

    Utility substation and distribution line protection

    Industrial plants and commercial power supply networks

    Outdoor installations up to 1000 meters altitude with Pollution Level II conditions

    Fuse Cutout Structure

    A dual bearing configuration forms the backbone of the cutout's mechanical design. The main bearing provides primary support and alignment for the fuse tube, while the secondary bearing reinforces structural integrity and ensures consistent contact pressure throughout switching and fault-clearing sequences.

    fuse-cutout-structure

    Fuse Cutout Accessories

    The HFSC-30F ships with a full complement of accessories engineered for safe operation and easy upkeep. A lower general bearing offers firm support and guided tube drop-out, while the arc extinguishing housing swiftly contains and quenches fault arcs. An American type fusible load featuring an integrated knife blade enables load-breaking and visible circuit isolation, and the 300A fusible load assures reliable interruption under high-current demands.

    fuse-cutout-accessories

    Technical parameter

    Electrical Characteristics

    Electrical characteristics Specification Unit
    Voltage 24~27 KV
    Current 100/200/300 A
    Frequency 50/60 Hz
    Power frequency withstand voltage to earth (1 min) 50 KV
    Power frequency withstand voltage phase to phase (1 min) 60 KV
    Impulse voltage to earth 150 KV
    Impulse voltage phase to phase 160 KV
    Breaking current 8 KA
    Creepage distance: 620 mm

    Spare Parts

    Spare parts Availability
    Mounting bracket with/without
    Arc shortening rod with/without
    Arc distinguish chamber with/without
    Fuse link without

    Material

    Component Material Specification
    Copper content for brass Brass (60~62%)
    Conductive parts material Copper with silver plated/Copper with tin plate
    Insulator Porcelain/Polymer
    Fuse tube Fiber glass

    Service Conditions

    Condition Parameter Rating Unit
    Environment maximum temperature 40 ℃
    Pollution level II —
    Altitude ≤1000 Meter

    Frequently Asked Questions

    What is the rated voltage and current capacity of this fuse cutout?

    The cutout is designed for operational voltages ranging between 24kV and 27kV at 50/60Hz frequency, with multiple current carrying specifications available at 100A, 200A, and 300A.

    How does the dual bearing configuration enhance cutout performance?

    The dual bearing system provides primary support and precision alignment for the fuse tube via the main bearing, while the secondary bearing reinforces structural stability and ensures uniform contact pressure during switching operations and fault interruption.

    What insulator material options are offered?

    The device is configurable with either lightweight polymer insulators—providing superior hydrophobic resistance against moisture and contamination—or traditional porcelain insulators.

    What are the recommended service conditions for installation?

    The unit is rated for outdoor installations up to an altitude of 1000 meters, an ambient operating temperature limit of up to 40°C, and under Pollution Level II environmental conditions.

    Does the cutout permit load-breaking under energized conditions?

    Yes, the integrated loadbreak functionality and arc extinguishing chamber permit the safe disconnection and visible isolation of live circuits under standard load operating conditions.

    What materials are used for the conductive parts and fuse tube?

    Conductive parts are manufactured from high-grade copper with silver plating or tin plating to ensure minimal electrical resistance and oxidation resistance, while the fuse tube is made of heavy-duty fiber glass.

    Inquire Now!

    If you have any needs, please feel free to contact me and I will be happy to serve you.

    Leave Your Message