inquiry
Leave Your Message
Products Categories
Featured Products

Y5(10)W-9J Surge Arrester

The Y5(10)W-9J is a gapless polymer-housed surge arrester rated 9kV with 5kA or 10kA discharge current. Designed for overhead distribution transformer protection, it clamps lightning impulse to 27kV and switching impulse to 23.8kV. Featuring zinc oxide varistors, stainless steel terminals, and optional disconnector and bird guard, it meets IEC 60099-4 for dependable overvoltage protection in polluted outdoor environments.

    Product Overview

    The Y5(10)W-9J is a 9kV gapless metal-oxide surge arrester purpose-built for distribution transformer protection on overhead lines. Its ZnO varistor core instantly diverts overvoltage energy to ground, limiting lightning residual voltage to 27kV and switching residual to 23.8kV. With a maximum continuous operating voltage of 7.65kV and high current withstand of 65kA/100kA, it handles moderate to severe lightning duty. The polymer housing provides excellent hydrophobicity and pollution resistance, while varistor diameter options (35mm to 42mm) allow energy rating customization. Class 1/Class 2, Design B per IEC 60099-4.

    Product Features

    ◆ Gapless ZnO varistor design for instantaneous surge response
    ◆ Low residual voltages: 27kV lightning, 23.8kV switching
    ◆ High current impulse withstand: 65kA / 100kA
    ◆ Long duration impulse withstand: 150A / 250A
    ◆ Varistor diameters: 35mm, 38mm, 40mm, 42mm
    ◆ Optional: bracket, disconnector, earth lead, bird guard, line clamp

    Product Advantages

    ● Rapid Overvoltage Clamping: Gapless ZnO design ensures immediate protection against lightning and switching surges.
    ● Strong Pollution Resistance: Polymer housing resists contaminants and moisture, ideal for heavy pollution areas.
    ● Customizable Energy Handling: Multiple varistor sizes and dual discharge ratings adapt to varying lightning exposure levels.
    ● Durable Connections: Stainless steel 304 terminals prevent corrosion and maintain low contact resistance over time.
    ● Enhanced Safety Options: Disconnector isolates failed units; bird guard cap prevents animal-related flashovers.

    Applications

    ◆ 9kV overhead distribution transformer protection
    ◆ Pole-mounted transformer surge protection in medium-voltage networks
    ◆ Distribution feeder and tap line lightning protection
    ◆ Switchgear and recloser overvoltage protection
    ◆ Rural electrification networks in lightning-prone regions

    Technical parameter

    Electrical characteristics Specification Unit
    Rated voltage of Surge arrreser 9 kV
    Nominal discharge current 5 10 kA
    Rated frequency 50 Hz
    Maximum continuous operating voltage 7.65 kV
    Steep current impulse residual voltage 33.7 kV(Crest)
    Lightning Impulse residual voltage 27 kV(Crest)
    Switching Impulse residual voltage 23.8 kV(Crest)
    Long duration current impulse withstand voltage 150 250 A
    High current impulses 65 100 kA (Crest)
    Rated Short-circuit current 20 / 12 / 6 / 0.6 ± 0.2 kA
    Class of Surge arrester Class 1 or Class 2
    Application Distribution type
    With or without gap Gapless
    Designation of arrester Design B

    Spare parts
    NEMA A or B mounting bracket with/without
    Disconnector with/without
    Earth lead with/without
    Bird guard cap with/without
    Line clamp with/without
    Upper terminal (incoming line) bolt size M12
    Lower termina (outgoing line) bolt size M10

    Material
    Upper terminal Stainless steel 304
    Housing Polymer type
    Color of housing Dark grey / light grey
    Varistor High quality zinc oxide varistor
    Size of Varistor 35mm / 38mm /40mm / 42mm

    Service conditions
    Environment maximum temperature 40 ℃
    Pollution level Heavy
    Altitude 1000 Meter